FRG-2 – Using Weakly Spin-Coupled Polaron Pair States for a Calibration Free Absolute Magnetometry

Objective:
A precise absolute magnetometer based on organic spintronics that is scalable to micron dimensions, has low cost and that is not adversely affected by environmental influences (temperature, air etc.).

Approach: Integrated bipolar MEH-PPV device above magnetic field strip lines for magnetic resonant excitation. The B-field is measured through spin-dependent current changes under magnetic resonance.

Results and Significance: For the p-conjugated polymer MEH-PPV, an ABSOLUTE sensitivity of

Figure: (a) Sketch of device design. (b) Device current change at an excitation frequency of 250MHz indicates presence of magnetic field with B=8.9mT